Hot and cold plate instrument

来源:本站 作者:玉研仪器 Time: 2016-09-21 Source: Site Author: Jade research instrument

Detailed introduction

Hot Cold Plate Analgesia Meter for Mice and Rats 测量动物对镇痛药物的疼痛反应极限 同时进行冷热痛觉测试,更多详情敬请来电咨询) Hot and cold plate pain tester (hot and cold plate test for rats and mice, hot and cold plate, hot cold plate analgesia meter for mice and rats ) Please contact us for details)


Model: 39 type (hot plate instrument), PE34 (hot and cold plate instrument)

 

The traditional hot plate test can only test the animal's pain response time, and can not be used for temperature rise test and repeated test due to the long cooling time. 热痛觉测试,用于测量动物对镇痛药物的疼痛反应极限,扩大了镇痛药物研究的范围。 PE34 uses a microprocessor to control the temperature rise and fall, and can perform cold pain test and hot pain test. It is used to measure the pain response limit of animals to analgesics and expand the scope of analgesic drugs research.

 

特点: Hot and cold plate pain tester main features:

 

快速升温和降温,每分钟可升降10℃,适合重复测试 温度稳定性为0.1℃ ØRapid heating and cooling, can rise and fall by 10 ℃ per minute, suitable for repeated testing. Temperature stability is 0.1 ℃

温度范围从0到70℃ Ø Temperature range from 0 to 70 ° C

时间精度为0.01秒 Ø Time accuracy is 0.01 seconds

冷热板大小: 4” x 8” Ø Hot and cold plate size: 4 ”x 8”

标准计算机打印口,输出 RS-232输出 ØStandard computer print port, output RS-232 output


Hot Cold Plate is used to measure the nociceptive threshold of analgesic compounds in mice and rats.

Conventional constant temperature hot plate tests only measure latencies of stronger narcotic agents.


Hot / Cold Plate Analgesia Meter widens the range of analgesia research to new levels. The unit is

microprocessor controlled and can be used for both incremental heating and cooling from any starting

temperature from 0 deg. c. to 70 deg. c in 0.1 degrees c. increments. The microprocessor monitors and

controls the rate of heating / cooling which can be set from 1 to 10 deg c. per minute. The front panel

display shows all test results including length of test in .01 sec. increments, starting temperature and

stopping temperature. The plate is uniformly heated / cooled at an adjustable rate and has automatic

upper / lower cut-off limits. All parameters are entered via front panel keypad. ie rate of temperature

increase / decrease, maximum / minimum temperature, date / time and animal number.



Related Literature:

[HTML]   Cell cycle inhibition limits development and maintenance of neuropathic pain following spinal cord injury

J Wu, Z Zhao , X Zhu, CL Renn, SG Dorsey, AI Faden -Pain, 2016-ncbi.nlm.nih.gov

… Hot and cold plate tests were used to assess the thermal hyperesthesia [8]. An incremental
hot / cold plate (PE34; IITC Life Sciences, Woodland Hills, CA) with a starting temperature of
30 ° C and the hot and cold ramps, set at the maximum rate of 10 ° C / min, was used to induce…


induced bladder hyperactivity and noxious input Transient receptor potential vanilloid 1 mediates nerve growth factor induced bladder hyperactivity and noxious input

B Frias, A Charrua, A Avelino, MC Michel …-BJU…, 2012-Wiley Online Library

… For 5 min. Latencies were determined before and 4 h after each NGF injection. For
that, animals were placed on the hot-plate apparatus (Series 8, model PE34, IITC
Life Sciences, Woodland Hills, CA, USA). The platform was…


HTML Voluntary exercise training: analysis of mice in uninjured, inflammatory, and nerve-injured pain states [ HTML ] Voluntary exercise training: analysis of mice in uninjured, inflammatory, and nerve-injured pain states

, BA Copits , JP Golden, RW Gereau IV - PloS one, 2015 - journals.plos.org TD Sheahan , BA Copits , JP Golden, RW Gereau IV -PloS one, 2015-journals.plos.org

… Values from both paws were averaged to determine withdrawal latency. Hot plate.
Prior to testing day, animals were individually acclimated to the hot plate chamber
(Model PE34 Series 8, IITC Life Science Inc.) for 15 min. On…


[HTML]   Evaluation of antinociceptive effect of methanolic leaf and root extracts of Clitoria ternatea Linn. In rats

L Kamilla, S Ramanathan, S Sasidharan-Indian journal of…, 2014-ncbi.nlm.nih.gov

… The hot plate test was used as previously described. [9] The heated surface of a hot plate analgesia
meter (model PE34, series 3, IITC Life Science Series, Woodland hills, USA) was maintained at
55 ± 1 ° C. Each animal was placed on the heated surface of the plate…


[PDF] Analgesic and antioxidant properties of ethanolic extract of Terminalia catappa L. leaves

, MN Mordi , S Ramanathan… - International journal of …, 2010 - academia.edu HV Annegowda , MN Mordi , S Ramanathan… -International journal of…, 2010-academia.edu

… Rats were placed on the heated surface of a hot plate analgesia meter (IITC Life Science Series
8, Model PE34, Victory Blvd, Woodland Hills, CA 91367, USA) maintained at 55 + 0.2 ° C. The time
taken for licking, shaking of forepaws or jumping was recorded as the index of…


HV Annegowda, MN Mordi, S. Ramanathan and SM Mansor

ISI Thomson-International Journal of Pharmacology, 2010-scialert.net

… Rats were placed on the heated surface of a hot plate analgesia meter (IITC Life Science Series
8, Model PE34, Victory Blvd, Woodland Hills, CA 91367, USA) maintained at 55 ± 0.2 ° C. The time
taken for licking, shaking of forepaws or jumping was recorded as the index of…


[HTML] Modality-specific peripheral antinociceptive effects of μ-opioid agonists on heat and mechanical stimuli: Contribution of sigma-1 receptors

Á Montilla-García, G Perazzoli , MÁ Tejada…-…, 2018-Elsevier

… Then the plantar side of the stimulated hindpaw was placed on the surface of a thermal
analgesiometer (Model PE34, Series 8, IITC Life Science Inc., Los Angeles, USA) previously
set at 55 ± 1 ° C until the animal showed a paw withdrawal response…